Undercuts in shaft reduce impairment of blood supply
Posterior hook offset
Fixation of lateral clavicle fractures and dislocations of the acromioclavicular joint. Smooth hook design
|
Clavicle Hook Locking Compression Plate
|
4 holes x 66mm x 12mm (Left) |
| 5 holes x 82mm x 12mm (Left) | |
| 6 holes x 98mm x 12mm (Left) | |
| 7 holes x 114mm x 12mm (Left) | |
| 4 holes x 66mm x 15mm (Left) | |
| 5 holes x 82mm x 15mm (Left) | |
| 6 holes x 98mm x 15mm (Left) | |
| 7 holes x 114mm x 15mm (Left) | |
| 4 holes x 66mm x 12mm (Right) | |
| 5 holes x 82mm x 12mm (Right) | |
| 6 holes x 98mm x 12mm (Right) | |
| 7 holes x 114mm x 12mm (Right) | |
| 4 holes x 66mm x 15mm (Right) | |
| 5 holes x 82mm x 15mm (Right) | |
| 6 holes x 98mm x 15mm (Right) | |
| 7 holes x 114mm x 15mm (Right) | |
| Width | 11.0mm |
| Matching Screw | 3.5 Locking Screw / 3.5 Cortical Screw / 4.0 Cancellous Screw |
| Material | Titanium |
| Surface Treatment | Micro-arc Oxidation |
| Qualification | CE/ISO13485/NMPA |
| Package | Sterile Packaging 1pcs/package |
| MOQ | 1 Pcs |
| Supply Ability | 1000+Pieces per Month |
Indications for clavicle fracture fixation can include:
Displaced fractures: Fractures where the broken bone ends are not aligned or properly positioned.
Fractures with skin tenting or risk of open fracture: If the fracture causes the overlying skin to tent or if there is a risk of the bone piercing through the skin, surgical intervention may be necessary.
Fractures with neurological or vascular compromise: Fractures that affect nearby nerves or blood vessels may require surgical treatment.
Multiple fragment fractures (comminuted fractures): Fractures with multiple bone fragments may require fixation to restore alignment and stability.
Non-union or delayed union: When the fracture fails to heal (non-union) or takes longer than expected to heal (delayed union), surgical intervention may be necessary to promote bone healing.
It is important to consult with an orthopedic surgeon who can assess your specific condition and determine the most appropriate treatment, including the use of clavicle fracture fixation implants, if necessary.
The plate is engineered to provide a unified fixation solution for both lateral clavicle fractures and acromioclavicular (AC) joint dislocations, stabilizing the bone fragments while preserving joint reduction.
The plate is fabricated from high-grade biocompatible titanium and undergoes a micro-arc oxidation surface treatment to optimize surface properties, wear resistance, and tissue compatibility.
The plate accommodates 3.5mm Locking Screws, 3.5mm Cortical Screws, and 4.0mm Cancellous Screws, providing surgical flexibility depending on bone density and fracture type.
The undercuts along the shaft minimize plate-to-bone contact, reducing impairment of the periosteal blood supply and promoting faster and more reliable bone union.
Plates are offered in dedicated left and right configurations with 4, 5, 6, and 7 holes (lengths: 66mm, 82mm, 98mm, and 114mm) and hook depths of either 12mm or 15mm.
The system complies with rigorous international quality standards, holding certifications including CE, ISO13485, and NMPA, delivered individually in sterile packaging.