The femoral neck antirotation instrument is a specialized medical device designed to assist orthopedic surgeons during hip surgery, particularly those involving the femoral neck. This device plays a vital role in ensuring femoral neck stability and proper alignment, which is crucial for successful outcomes in hip replacements and fracture fixation procedures.
| Serial No. | English Name | Product Code | Specification | Quantity |
|---|---|---|---|---|
| 1 | Angled Guide | 10021001 | 130° | 1 |
| 2 | Correction Guide | 10021002 | - | 1 |
| 3 | Guide Wire | 10021003 | φ3.2*400 | 4 |
| 4 | Direct Measuring Device | 10021004 | - | 1 |
| 5 | Drill Bit | 10021005 | φ10.2*251 | 1 |
| 6 | Reamer | 10021006 | φ12.5 | 1 |
| 7 | Nut for Reamer | 10021007 | - | 1 |
| 8 | Insertion Handle | 10021008 | - | 1 |
| 9 | Insert, for Insertion Handle | 10021009 | - | 1 |
| 10 | Multifunction Rod | 10021010 | - | 1 |
| 11 | Drill Bit | 10021011 | φ4.3*413 | 2 |
| 12 | Drill Stopper | 10021012 | - | 1 |
| 13 | Drill Guide | 10021013 | - | 1 |
| 14 | Screwdriver Shaft | 10021014 | T25 | 1 |
| 15 | Screwdriver Shaft | 10021015 | SW3.5 | 1 |
| 16 | Slap Hammer | 10021016 | - | 1 |
| 17 | Depth Gauge | 10021017 | - | 1 |
| 18 | Torque Limiter | 10021018 | 4.0N.m | 1 |
| 19 | Quick Coupling Handle | 10021019 | - | 1 |
| 20 | Conversion Chuck | 10021020 | - | 1 |
| 21 | Protection Sleeve | 10021022 | - | 1 |
| 22 | Wrench | 10021023 | - | 1 |
| 23 | Instrument Box | 10021021 | - | 1 |
The FNAS is designed to provide stable fixation and rotational control during femoral neck fracture repairs and hip procedures, preventing post-operative displacement and promoting optimal bone healing.
They are primarily utilized in orthopedic surgery for femoral neck fracture internal fixation, reconstructive hip surgeries, and selected osteotomy procedures where anatomical precision and antirotation are required.
The included 130° Angled Guide facilitates accurate drill positioning and guide wire insertion aligned with the anatomical neck-shaft angle of the femur, ensuring reproducible implant placement.
The calibrated 4.0N.m torque limiter prevents over-tightening during screw fixation, reducing the risk of bone stripping and ensuring uniform holding strength.
The system is housed in a dedicated, high-durability Instrument Box configured for systematic component arrangement, standard hospital autoclaving, and rapid identification in the operating room.
Yes, the φ3.2*400 guide wires are manufactured from medical-grade surgical alloy to provide distinct radio-opacity for real-time X-ray verification during navigation and placement.